Category: NS0-173 exam questions

[2021.4] New, Free | NetApp NS0-173 Practice Test, NetApp NS0-173 Pdf[2021.4] New, Free | NetApp NS0-173 Practice Test, NetApp NS0-173 Pdf

Get the newest free complete NetApp NS0-173 exam dumps! Go https://www.pass4itsure.com/ns0-173.html (Q&As: 60 ). Best 100% valid up-to-date actual NetApp NS0-173 dumps that bring you the best results. You can get 100% free updates on NetApp NS0-173 practice test questions, NS0-173 pdf here.

[free pdf] NetApp NS0-173 pdf download from google drive https://drive.google.com/file/d/1HAd-H2qFOvSa8S_gNIT5UBXx2cYy1wJZ/view?usp=sharing

Latest NetApp NS0-173 Exam Questions From Youtube

https://youtu.be/3yPNKxZXmX4

NetApp NS0-173 Practice Test Q1-Q13 Free

QUESTION 1
A customer with a FlexPod Express configuration is currently operating Linux servers. The company wants to move to a
The windows-centralized access method for the NetApp storage component.
In this scenario, which two ONTAP features must be configured? (Choose two.)
A. Active Directory security model
B. SVM with the SMB protocol enabled
C. Workgroup security model
D. SVM with the NFS protocol enabled
Correct Answer: AB


QUESTION 2
A customer is designing a FlexPod solution with VMware 6.x in a SAN boot environment using FCoE. The customer has
predetermined the WWPN values for the NetApp LIFs and the UCS vHBAs. The customer is now working on the design
workflow for the SAN boot process.
In this scenario, which three FlexPod environment objects are required for SAN connectivity? (Choose three.)
A. NetApp export policies
B. UCS boot policies
C. UCS IQN pools
D. initiator groups
E. FC zones
Correct Answer: ABC


QUESTION 3
You are configuring Cisco UCS servers for FC SAN boot and want to perform zoning on your Cisco Nexus 5000 series
switches.
In this scenario, which statement is correct?
A. The corresponding FC ports on your NetApp storage array must be configured in LACP mode.
B. An iSCSI license on the NetApp storage controller is required.
C. SAN links are required between the Cisco Fabric Interconnects and the Nexus 5000 switches.
D. FC zoning on the Nexus series switches is not supported; zoning can be done only on the Cisco Fabric
Interconnects.
Correct Answer: D
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/b_UCSM_GUI_Configuration_Guide_2_2_chapter_011011.html


QUESTION 4
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric
interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?
A. 2204XP.
B. 2208XP
C. 2232
D. 2304
Correct Answer: A
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that
connect the blade chassis to the fabric interconnect. Reference: https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17644224.pdf

QUESTION 5
Click the Exhibit button.

NS0-173 exam questions-q5

A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two
configurations shown in the exhibit satisfy the customer\\’s requirements? (Choose two.)
A. I.
B. II.
C. III.
D. IV
Correct Answer: CD


QUESTION 6
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?
A. MDS9148>show fcfwd
B. MDS9148>show fcdomain
C. MDS9148>show fcc
D. MDS9148>show flogi database
Correct Answer: D
Reference: https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-1121.pdf

QUESTION 7
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis and ACI.
In this scenario, which two network switches are required? (Choose two.)
A. leaf switch
B. core switch
C. cluster interconnect switch D. spine switch
Correct Answer: AD
Reference: https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/applicationcentricinfrastructure/white-paper-c11-737909.html

QUESTION 8
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage
volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a
support case? (Choose three.)
A. Cisco
B. VMware
C. Microsoft
D. NetApp
E. Red Hat
Correct Answer: ADE
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_openstack_osp6_design.html


QUESTION 9
Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and
Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP storage cluster.
Which configuration is valid for expansion?
A. Use the existing Nexus 93108 switches for the cluster interconnect.
B. Add two Nexus 3232C switches for the cluster interconnect.
C. Add two Nexus 93108 switches for the cluster interconnect.
D. Add one Nexus 3232C switch for the cluster interconnect.
Correct Answer: B


QUESTION 10
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution
with the Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)
A. Cluster mode
B. Direct Connect mode
C. SingleConnect mode
D. DualWire Management mode
E. Multipath mode
Correct Answer: BCD
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used
exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the
data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire
management. SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card
connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack-Mount Server
directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C-Series Rack-Mount Servers
using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system.
This connection uses a single connection from each VIC to each FI.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_CSeriesIntegration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

QUESTION 11
Click the Exhibit button.

NS0-173 exam questions-q11

You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the
SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?
A. two 1GbE NICs
B. two 10GbE CNAs
C. two 10GbE NICs
D. two 8Gb HBAs
Correct Answer: C


QUESTION 12
Which port type would you configure when you connect a chassis to the Cisco Fabric Interconnects?
A. Ethernet uplink ports
B. FC storage ports
C. server ports
D. appliance ports
Correct Answer: B
Reference: https://www.netapp.com/media/12424-tr4036.pdf (16)


QUESTION 13
An architect is designing a FlexPod environment with Cisco Nexus 5000 switches to SAN boot all of the ESXi hosts over
FC.
In this scenario, what should the LUN ID number be?
A. LUN 2
B. LUN 3
C. LUN 0
D. LUN 1
Correct Answer: C
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_50_M3.html

NetApp NS0-173 PDF Free Download

NetApp NS0-173 pdf 100% free https://drive.google.com/file/d/1HAd-H2qFOvSa8S_gNIT5UBXx2cYy1wJZ/view?usp=sharing

Pass4itsure Special Discount Share:

Pass4itsure NetApp exam 15% discount with coupon: NetApp

Finish:

Free share latest NetApp NS0-173 pdf, NetApp NS0-173 practice questions, NetApp NS0-173 exam video!

Latest NetApp NS0-173 questions answers in order to lead every candidate towards a brighter and better future. Select https://www.pass4itsure.com/ns0-173.html to get complete NetApp NS0-173 dumps practice exam questions and answers. Wish you success!

NetApp NS0-173 pdf free download https://drive.google.com/file/d/1HAd-H2qFOvSa8S_gNIT5UBXx2cYy1wJZ/view?usp=sharing